Skip to content

Error

FX-SCH-A-000911: The payee contact's email entry needs one address element

In short

Error: fails the selected checks.

FX-SCH-A-000911 means an email entry for the payee's contact contains no ram:URIID element or contains more than one. Make the email entry contain exactly one ram:URIID.

On this page

What it means

Within the payee (BG-10), each ram:DefinedTradeContact/ram:EmailURIUniversalCommunication must contain exactly one ram:URIID child element. An empty ram:URIID still counts as one; this rule does not check whether the email address is populated or valid.

Why it matters

The contact's email entry has a defined structure with one element for the address.

How to fix it

In ram:PayeeTradeParty/ram:DefinedTradeContact/ram:EmailURIUniversalCommunication, add the missing ram:URIID with the correct email address or remove extra ram:URIID elements. If you are not supplying an email address, remove the whole email entry rather than just its child element. Regenerate and recheck your file.

Once the file is corrected, check it again for free: Validate a ZUGFeRD invoice

Or fix the invoice in a form and download the corrected file, for 1 credit: Fix a rejected e-invoice Beta

The rule as published

Element 'ram:URIID' must occur exactly 1 times.

Where this rule applies

Rule set Version
Factur-X 1.09 EXTENDED 1.0.9-2
ZUGFeRD 2.5 EXTENDED 2.5.2
Rule text from phive-rules 4.6.4.

Check your file

Drop your e-invoice to see whether FX-SCH-A-000911 still fails, and which other rules do.

Updated 6 November 2026