Skip to content

Error

FX-SCH-A-000905: Each invoicer electronic address entry needs one identifier

In short

Error: fails the selected checks.

FX-SCH-A-000905 means an electronic address entry for the invoicer contains no ram:URIID element or contains more than one. Make that entry contain exactly one ram:URIID for the address.

On this page

What it means

Each ram:InvoicerTradeParty/ram:URIUniversalCommunication must contain exactly one ram:URIID child element. An empty ram:URIID still counts as one; this rule does not check whether its address text is populated or valid.

Why it matters

A single identifier element gives software one defined place to read the invoicer's electronic address.

How to fix it

In ram:InvoicerTradeParty/ram:URIUniversalCommunication, add the missing ram:URIID with the correct electronic address or remove extra ram:URIID elements. If you are not supplying an electronic address, remove the whole communication entry rather than leaving it without a child element. Regenerate and recheck your file.

Once the file is corrected, check it again for free: Validate a ZUGFeRD invoice

Or fix the invoice in a form and download the corrected file, for 1 credit: Fix a rejected e-invoice Beta

The rule as published

Element 'ram:URIID' must occur exactly 1 times.

Where this rule applies

Rule set Version
Factur-X 1.09 EXTENDED 1.0.9-2
ZUGFeRD 2.5 EXTENDED 2.5.2
Rule text from phive-rules 4.6.4.

Check your file

Drop your e-invoice to see whether FX-SCH-A-000905 still fails, and which other rules do.

Updated 6 November 2026