Error

FX-SCH-A-000477: Keep one charge indicator on an invoice-level charge

In short

Error: fails the selected checks.

FX-SCH-A-000477 means an invoice-level entry selected as a charge (BG-21) contains more than one ram:ChargeIndicator element. Remove the duplicate elements and keep one indicator that correctly describes the entry, using true for a charge.

On this page

What it means

Under ram:ApplicableHeaderTradeSettlement, this rule selects ram:SpecifiedTradeAllowanceCharge entries where at least one ram:ChargeIndicator/udt:Indicator has the text true. It then requires exactly one ram:ChargeIndicator element. A missing indicator cannot trigger this particular rule because the entry would not be selected. The test counts ram:ChargeIndicator elements, not their udt:Indicator children.

Why it matters

The profile requires one charge marker in each selected entry. Repeated markers break that structure even when they all contain true and describe the same treatment.

How to fix it

In the affected ram:SpecifiedTradeAllowanceCharge, remove duplicate ram:ChargeIndicator elements. If the entry is a charge, keep one containing udt:Indicator with the text true. If it is actually a discount (BG-20), correct the single indicator to false instead. Export the corrected invoice and check it again.

Once the file is corrected, check it again for free: Validate a ZUGFeRD invoice

Or fix the invoice in a form and download the corrected file, for 1 credit: Fix a rejected e-invoice Beta

The rule as published

Element 'ram:ChargeIndicator' must occur exactly 1 times.

Where this rule applies

Rule set Version
Factur-X 1.09 BASIC WL 1.0.9-2
Factur-X 1.09 BASIC 1.0.9-2
Factur-X 1.09 EN 16931 1.0.9-2
Factur-X 1.09 EXTENDED 1.0.9-2
ZUGFeRD 2.5 BASIC WL 2.5.2
ZUGFeRD 2.5 BASIC 2.5.2
ZUGFeRD 2.5 EN 16931 2.5.2
ZUGFeRD 2.5 EXTENDED 2.5.2
Rule text from phive-rules 4.6.4.

Check your file

Drop your e-invoice to see whether FX-SCH-A-000477 still fails, and which other rules do.

Updated 6 November 2026