Skip to content

Warning

CII-SR-061: Remove the variable measure indicator element

In short

Warning: worth checking.

CII-SR-061 warns that a CII invoice line contains ram:VariableMeasureIndicator. Remove this element from the exported invoice. Setting its value to false does not clear this rule.

On this page

What it means

The test checks that the line's ram:SpecifiedTradeProduct, representing item information (BG-31), has no direct ram:VariableMeasureIndicator child. It checks whether the element exists, regardless of its value.

Why it matters

EN 16931 does not use this separate indicator in the product details. This rule does not require you to change how you measure or price the product.

How to fix it

Omit ram:VariableMeasureIndicator from the CII export rather than changing an operational variable measure or catch-weight setting you still need. Keep the actual invoiced quantity (BT-129) and its unit of measure (BT-130). If your software keeps including the element, ask its supplier to correct the export. Export the revised file and check it again.

Once the file is corrected, check it again for free: Validate an invoice against EN 16931

Or fix the invoice in a form and download the corrected file, for 1 credit: Fix a rejected e-invoice

The rule as published

VariableMeasureIndicator should not be present

Where this rule applies

Rule set Version
EN 16931 (CII) 1.3.17
XRechnung 3.0 (CII) 3.0.2
NLCIUS (CII) 1.0.3.13
France CTC (CII) 1.4.0-04
Rule text from phive-rules 4.6.4.

Check your file

Drop your e-invoice to see whether CII-SR-061 still fails, and which other rules do.

Updated 6 November 2026