CII-DT-025: Remove SectionName from document references

In short

Fatal: fails the selected checks.

CII-DT-025 means a CII document reference contains ram:SectionName. This element is not allowed on any document reference. Remove it from the affected reference.

On this page

What it means

Every CII reference element whose name ends in ReferencedDocument must be free of ram:SectionName, which identifies a section or chapter of the referenced document. The test has no exceptions.

Why it matters

This CII mapping does not provide a field for a referenced document's section name.

How to fix it

Remove ram:SectionName from the contract, order or other affected reference. If you need to explain which section applies, include that information in the invoice note (BT-22). If your invoicing software keeps adding the element, ask its supplier to correct the CII export. Export the corrected file and recheck it.

Once the file is corrected, check it again for free: Validate an invoice against EN 16931

Or fix the invoice in a form and download the corrected file, for 1 credit: Fix a rejected e-invoice

The rule as published

SectionName should not be present

Where this rule applies

Rule set Version
EN 16931 (CII) 1.3.17
XRechnung 3.0 (CII) 3.0.2
NLCIUS (CII) 1.0.3.13
France CTC (CII) 1.4.0-04
Rule text from phive-rules 4.6.4.

Check your file

Drop your e-invoice to see whether CII-DT-025 still fails, and which other rules do.