Error

FX-SCH-A-000829: The delivery party's electronic address needs one address field

In short

Error: fails the selected checks.

FX-SCH-A-000829 means an electronic-address block for the delivery party has no ram:URIID element or has more than one. Make sure that ram:URIUniversalCommunication block contains exactly one ram:URIID.

On this page

What it means

For each ram:URIUniversalCommunication under ram:ShipToTradeParty in the header delivery section, this rule requires exactly one direct ram:URIID child. It counts address elements; it does not check whether the address text is empty or correct.

Why it matters

The Extended profile uses one ram:URIID field for the address within each communication block. A missing or repeated field does not match that structure.

How to fix it

For the delivery party's electronic address, keep one ram:URIID containing the intended address inside each ram:URIUniversalCommunication block. Remove extra ram:URIID elements. If an electronic-address block is not required for your invoice, remove the whole block rather than leaving it incomplete. Export and recheck.

Once the file is corrected, check it again for free: Validate a ZUGFeRD invoice

Or fix the invoice in a form and download the corrected file, for 1 credit: Fix a rejected e-invoice Beta

The rule as published

Element 'ram:URIID' must occur exactly 1 times.

Where this rule applies

Rule set Version
Factur-X 1.09 EXTENDED 1.0.9-2
ZUGFeRD 2.5 EXTENDED 2.5.2
Rule text from phive-rules 4.6.4.

Check your file

Drop your e-invoice to see whether FX-SCH-A-000829 still fails, and which other rules do.

Updated 6 November 2026