Skip to content

Error

FX-SCH-A-000709: Include exactly one end user name field

In short

Error: fails the selected checks.

FX-SCH-A-000709 means a product end user block in your invoice has no ram:Name element or has more than one. Include one ram:Name containing the end user's name.

On this page

What it means

Each ram:ProductEndUserTradeParty under ram:ApplicableHeaderTradeAgreement must contain exactly one direct ram:Name child. This counts elements; it does not check whether the name text is empty.

Why it matters

The Extended profile requires one name field in each product end user block.

How to fix it

In your CII XML, check ram:Name directly inside ram:ProductEndUserTradeParty. Add the missing element with the correct end user's name, or remove extra name elements while keeping the correct one. Export the corrected file and recheck it.

Once the file is corrected, check it again for free: Validate a ZUGFeRD invoice

Or fix the invoice in a form and download the corrected file, for 1 credit: Fix a rejected e-invoice Beta

The rule as published

Element 'ram:Name' must occur exactly 1 times.

Where this rule applies

Rule set Version
Factur-X 1.09 EXTENDED 1.0.9-2
ZUGFeRD 2.5 EXTENDED 2.5.2
Rule text from phive-rules 4.6.4.